Scalable Flatpack Power System Eltek Rectiverter 54KVA 220Vdc EN 60950-1

  • 1
  • 2
  • 3

Brand Name : Eltek

Model Number : CIEJ3643.4xxx

Certification : CE.UL

Place of Origin : CN

MOQ : 1

Payment Terms : L/C,T/T

Supply Ability : 400 sets /month

Delivery Time : 12 weeks

Packaging Details : wooden cartons

Brand : Eltek

Produft name : Indoor Rectiverter scable cabinet

Protection level : SPD , LLVD. BLVD

Input current : 240ADC

Max input AC : 475 VAC

Max input DC : 290VDC

Mains configuration : 230/400VAC

Max AC output : 415AVC

DC output current : 200 ADC

DC output max voltage : 290 VDC

Dimension : 600 x 2000 x 600 mm

Weight : 300kg

Contact Now

Eltek rectiverter Indoor system Scalable system 18-54KVA 220Vdc AC backup power for 400 VAC Or 230Vac (CIEJ3643.4xxx )

Scalable Flatpack Power System Eltek Rectiverter 54KVA 220Vdc EN 60950-1

Eltek rectiverter Indoor system Scalable system 18-54KVA 220Vdc AC backup power for 400 VAC Or 230Vac (CIEJ3643.4xxx )

The scalable Rectiverter indoor system provides AC backup power for

400 VAC 3-phase or 230 VAC 1-phase loads, and 220 VDC power for battery

charging and optional DC loads. The flexible DC output can be set to

recharge large battery backup with protection time up to 10 hours.

In combination with the optional B-input (dual AC input) eliminates the

need for a traditional ATS (Automatic Transfer Switch). Where the switch from A to B input

, is a seamless operation with no

interruption on the AC load

.

In combination with the optional B-input (dual AC input) eliminates the need for a traditional ATS (Automatic Transfer Switch).Where the switch from A to B input, is a seamless operation with no interruption on the AC load.

When configured with dual AC input for use as an AC UPS, it classifies as - VFI SS 111 according to EN 62040-3


Key features

l 400 VAC 3 phase (Y) input

l 400 VAC 3 phase (Y) output

l 220VDC input/output

l Max 54 kVA / 43,2 kW AC output

l Max 43,2 kW DC output

l Protected bulk AC output

l A+B option (dual AC input)

l Manual bypass option

l Up to 4 battery strings

l Built in transfer technology

l 150% overload capability, 15S

l 600% quick trip current 20 ms

l Hot pluggable

l Smartpack2 controller

l Operates in paralell with Flatpack2 rectifiers

l Global compliance

l Patented HE technology


Parameters :


Models / ordering information 54 kVA + 48 kW A-Input 54 kVA + 48 kW B-Input
Product family
CIEJ3643.4xxx CIEJ3643.4 xxx
AC OUTPUT DATA
Voltage (default) / (adjustable range)1)
400 VAC 3 phase (Y) / 346-415 VAC
Frequency (default inverter mode)
50 Hz (adaptive)
Frequency (set-able inverter mode)
50Hz, 60Hz or last synced 50/60Hz (adaptive)
Power maximum (continuous / overload (<15s) )
43,2 kW (54 kVA) / 72 kVA
Current maximum/phase (continuous / overload (<15s) )
78ARMS / 104,4ARMS
Current (maximum) Quick trip/phase (20ms)
380A (6 x nominal)
Hold up (Voltage dips) (before switching to battery)
> 5 ms @ 43,2 kW load
THD
< 1.5 % at resistive load
Output features

Module: Fuse in L and N , Hot pluggable

100 A MCCB, AC output individual screw terminals 70 mm2 for L1-L3, N & PE

DC OUTPUT DATA
Voltage (default) / (adjustable range)
122,5 VDC / 97 - 145 VDC
Power (maximum @nominal input)
43,2 kW 2)
Current (maximum @VOUT ≤ 48 VDC)
400 A 2)
Hold up time, maximum output power
>10ms; VOUT > 97 VDC
Output features

Short circuit proof, Over voltage Shutdown

Battery input /output connection to M10 bolt

INPUT DATA
AC Mains Input Voltage(3 phase Y)
320-475 VAC,
AC Current/phase(at nominal output voltage) (depending on module type) 92-138 ARMS 4)
Frequency (default: sync range)
47-53 & 57-63 Hz
Frequency (set-able: sync range)
47-53 Hz, 57-63 Hz or both (adaptive)
Power Factor / THD
> 0.99 at 50% load or more / < 3.5%
DC Voltage nominal / extended range (no overload)3)
102 - 145 VDC / 90 - 145 VDC
DC Current (maximum)
450 A / 648 A during overload (15s)
Input features

Module : Fuse in L and N, Hot pluggable, Varistor, Hot pluggable

160 A MCCB, AC input individual screw terminals 70 mm2 for L1-L3, N & PE

BATTERY & LOAD BREAKER
2-pole battery breaker
2*MCCB 630 A 1*MCCB 880 A
2-pole load breaker
- 1*MCCB 630 A
OPTIONS
B-input maximum power (with FP2 HE, 2 kW rectifiers)
48 kW
Manual Bypass switch
2*160 A
OTHER SPECIFICATION
Efficiency >96% (mains mode (AC/AC and AC/DC)), >94% (inverter mode (DC/AC))
Protection Class IP 20

Operating temperature -40 to +55°C (-40 to +131°F), humidity 5 - 95% RH non-condensing
Storage temperature -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing
Dimensions[WxDxH] / Weight 600 x 600x 2000mm (23,7 x 23,7 x 78,8”) / 300 kg (1100 lbs)
DESIGN STANDARDS
Electrical safety EN 60950-1, EN 62040-1 UPS safety
EMC

ETSI EN 300 386 V.1.6.1, FCC CFR 47 Part 15

EN 61000-6-1 /-2/-4/-5



Environment

ETSI EN 300 019: 2-1 (Class 1.2), 2-2 (Class 2.3)

Normal operating conditions to be as per IEC/EN 62040-3:2011 clause 4.2

Other operating conditions as per IEC 62040-3:2011 clause 4.3, must be advised 2011/65/EU (RoHS) & 2012/19/EU (WEEE)

1) Output voltage ranges configured in factory and have individual keying in top chassis

3) 90 - 102 VDC: reduced performance - no power boost and increased voltage THD on AC output.

2) AC load has priority. Maximum available DC output power and current is dependent on instant AC load and AC input voltage; i.e maximum 28 ,8kW/260 A at full AC power and nominal input for 230VAC.

4) If DC voltage is pulled below 97 V the input current may increase above this level



* The indoor Rectiverter Cabinet with AC &DC feed in one cabinet

Scalable Flatpack Power System Eltek Rectiverter 54KVA 220Vdc EN 60950-1


Scalable Flatpack Power System Eltek Rectiverter 54KVA 220Vdc EN 60950-1



Related Products :


Scalable Flatpack Power System Eltek Rectiverter 54KVA 220Vdc EN 60950-1Scalable Flatpack Power System Eltek Rectiverter 54KVA 220Vdc EN 60950-1



Scalable Flatpack Power System Eltek Rectiverter 54KVA 220Vdc EN 60950-1Scalable Flatpack Power System Eltek Rectiverter 54KVA 220Vdc EN 60950-1

Scalable Flatpack Power System Eltek Rectiverter 54KVA 220Vdc EN 60950-1


Solutions

Leveraging the power of communication technology, we build all - round services for telecom enterprises at home and abroad. We use high - tech equipment such as drones and sensors for on - site surveys, apply cloud computing and machine learning technologies to formulate professional plans, and utilize the Internet of Things and 5G technology to achieve rapid technical support and remote maintenance. We have a team with strong technological capabilities and numerous technology partners in the global arena, driving the intelligent upgrading of telecommunications services.



FAQ :

1.Can I ask for samples and know the sample price?

A: Samples are available. The price of samples is consistent with the bulk price, and you will be responsible for the sample freight.


2.How does your company resolve quality - related issues?

A: Having been in the industry for nearly 10 years, we value our brand image. When a quality problem occurs, we will conduct a thorough analysis. If it's our responsibility, we will handle it according to the contract terms, and our service team will provide you with full support.


3.What about the quality level of your products?

A: Our products are 100% original and newly packaged. We perform a strict quality check on each product before sending it out to ensure its excellent quality.


4.How long does the quality guarantee last?

A: Our products enjoy a 1 - year quality guarantee. During this period, we will deal with any quality - related problems promptly and effectively.


5.What's the process for dealing with defective goods?

A: For any defective products within the guarantee period, we will bear the shipping cost for the return and arrange for a replacement to ensure your shopping experience is worry - free.






Product Tags:

Scalable Flatpack Power System 54KVA

      

Eltek rectiverter 54KVA 220Vdc

      

Eltek rectiverter EN 60950-1

      
China Scalable Flatpack Power System Eltek Rectiverter 54KVA 220Vdc EN 60950-1 wholesale

Scalable Flatpack Power System Eltek Rectiverter 54KVA 220Vdc EN 60950-1 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Beijing Ding Ding Future Technology Co.Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)